Pinnacle Systems Universal Safety Controller HUB User Manual
Page 21

Page 16 of 18
Device # fault
No such Device
Universal Safety Controller HUB was incorrectly
programmed or corrupted.
Mstr Mat Fault Slv Mat Fault
above limit above limit
Master or Slave Mat circuit detected an incorrect voltage
on the Mat terminals. Possibly incorrect wiring or jumper
configuration.
EDM K1K2 Fault EDM K1K2 Fault
On should be Off Off should be On
External Device Monitoring (external Relay checking)
found in wrong condition. Check wiring through external
relays (N.C. contacts).
Mute Fault Mute Fault
K1K2 Master 1K2 Slave
Master or Slave detected that the Mute-out Inputs (for
Channel C) were not in opposite states as required.
Check your Mute-Out signals and timing of them.
Mute Fault Mute Fault
K3K4 Master K3K4 Slave
Master or Slave detected that the Mute-out Inputs (for
Channel D) were not in opposite states as required.
Check your Mute-Out signals and timing of them.