Datasheet nsd safety mat controller modules
www.pinnaclesystems.com
www.pinnaclesystems.com
1
Page 1 / 2
Datasheet
Item No. R1.188.3580.0
Device for monitoring of safety-related circuits SNO 4083KM-A DC 24V
Base unit also for elevators EN 81-1/2 and heaters EN50156-1
single-channel or two-channel control, automatic or manual reset
with monitoring, cross circuit monitoring, 3 enabling current paths, 1
signalling output, DC 24 V, screw-terminals pluggable
Item No.
R1.188.3580.0
EAN
4049088070884
order unit
1 Piece(s)
Approvals
Technical data
General
ArticlePrice
udp_no_price
Function display
3 LED, green
Creepage distances and clearances between the circuits
EN 60664-1
Protection degree according to DIN EN 60529 (housing)
IP40
Protection degree according to DIN EN 60529 (terminals)
IP20
Ambient temperature min.
-25 °C
Ambient temperature max.
65 °C
Wire ranges screw terminals, fine-stranded / solid
1 x 0,14 mm² - 2,5 mm² / 2 x 0,14 mm² - 0,75 mm²
Wire ranges screw terminals,fine-stranded with ferrules
1 x 0,25 mm² - 2,5 mm² / 2 x 0,25 mm² - 0,5 mm²
Permissible torque min.
0.5 Nm
Permissible torque max.
0.6 Nm
Tightening moment
0.6 Nm
Wire range cage clamp terminals
2 x 0,25mm² - 1,5mm²
Weight
0.2 kg
Standards
EN ISO 13849-1 EN 62061 EN 81-1 EN 50156-1
Suited for safety functions
Yes
Category according to EN 954-1
4
Muting possible
No
Feedback circuit
Yes
Start contact
Yes
Performance level acc. to EN ISO 13849-1
e
Rail mounting possible
Yes
Connection Data
Detachable clamps
Yes
Type of electric connection
Screw connection
Application
Model
Basic device
Suitable for monitoring of magnetic switches
Yes
Suitable for monitoring of proximity switches
Yes
Datasheet
NSD Safety Mat Controller Modules
Both Modules are compliant to OSHA & ANSI Standards -
EN ISO 13849-1 EN 62061 EN 81-1 EN 50156-1
NSD-3580
24 VDC
NSD-3590
115 TO 230 VAC