Diagnostics display – Pinnacle Systems Universal Safety Controller HUB User Manual
Page 18

Page 13 of 18
Diagnostics Display
OK OK ETHERNET
Total Devices xx Total Devices xx
If all devices attached are in there normal state (i.e. E-Stop
devices closed, Palm buttons OFF, Mute-out in guarded
condition, reset buttons in OFF) then the Diagnostics
Display will read “OK” and show the total number of
devices programmed into the HUB. If ETHERNET
appears on the display, this indicates that you have the
ETHERNET option and someone is currently accessing
that particular HUB device.
ESTOP-2W DEV#xx
Term# Ayy - Bzz
Indicates 2 wire device #xx has opened up. The Terminal
numbers that this device is connected to are shown on
the second line.
ESTOP-3W DEV#xx ESTOP-3W DEV#xx
Trm# Aww Byy Bzz Trm# Aww Ayy Bzz
Indicates 3 wire device #xx has opened up. The Terminal
numbers that this device is connected to are shown on
the second line.
ESTOP-4W Dev#xx
T# Avv-ww Byy-zz
Indicates a 4 wire device #xx has opened up. The Terminal
numbers that this device is connected to are shown on
the second line.
On Mat Dev#xx
T# Avv-ww Byy-zz
Indicates the 4 wire Mat(s) circuit is shorted (on mat)
and the Device number. The Terminal numbers that this
device is connected to are shown on the second line.
Mute ON RLY C Mute ON RLY D
Dev#xx T#Ayy-Bzz Dev#xx T#Ayy-Bzz
Indicates Mute-Out device for Relay C or D now active
(MUTED). The Device# and the Terminal numbers that
this device is connected to are shown on the second line.
Palms Active
Dev#xx T#Ayy-Bzz
Both Palm devices activated together within 1/4 second
of each other and held down. The Device number and
the Terminal numbers that this device is connected to are
shown on the second line.
Palm time out
Dev#xx T#Ayy-Bzz
Both Palms were NOT activated with 1/4sec of each
other. To clear this fault both palms must be released
(opened). The Device number and the Terminal num-
bers that this device is connected to are shown on the
second line.
RST pushd RLY C RST pushd RLY D
Dev#xx T#Ayy-Bzz Dev#xx T#Ayy-Bzz
Latching Relay Reset Button for Relay C or D was pushed
(cycled open/closed). To further reset relay outputs, you
must clear (open) the device back up). The Device number
and the Terminal numbers that this device is connected to
are shown on the second line.
CI active RLY C CI active RLY D
Dev#xx T#Ayy-Bzz Dev#xx T#Ayy-Bzz
Cincinnati Interface device for checking Relay C or D is
active (Relay output turned OFF). This Device must open
before the Relay output will attempt to turn back on. The
Device numberand the Terminal numbers that this device
is connected to are shown on the second line.
Limit SW DEV#xx
Term# Ayy - Bzz
Indicates 2 wire device #xx has activated. The Terminal
numbers that this device is connected to are shown on the
second line.