Appendix a: i/o address function, A: i/o a, Ppendix – NEXCOM VMC 100 User Manual
Page 83: Ddress, Unction

Copyright © 2014 NEXCOM International Co., Ltd. All rights reserved
69
VMC 100/1100 Series User Manual
Appendix A: I/O Address Function
a
PPendIx
a: I/o a
ddress
f
unCtIon
IO ADDRESS:0EE0H~0EEFH
(*) for default setting
1. Ignition_status/ Battery_status/12V_status/
I/O port : 0EE0H
Bit 0: Reseversion
Bit 1: Reseversion
Bit 2: Ignition (read only)
0: OFF
1: ON
Bit 3: Status of Car Battery
0: Car Battery is OK
1: Car Battery is Low voltage
Bit 4: Status of +12V output
0: circuit normal(under 4A)
1: over circuit(over 4A)
Bit 5: Status of Car Battery bypass output
0: circuit normal(under 4A)
1: over circuit(over 4A)
Bit 4 and Bit 5: The action will delay 10ms~15ms