beautypg.com

NEXCOM VTC 2100 User Manual

Page 17

background image

Copyright © 2010 NEXCOM International Co., Ltd. All Rights Reserved.

4

VTC 2100 User Manual

Chapter 1: Product Introduction

Power Management
• Power-on delay time is selectable by BIOS to disable and enable in 10sec

/ 30sec / 1min / 5min / 10 min / 15min / 30min / 1hr.

• Power-off delay time is selectable by BIOS to disable and enable in 20sec

/ 1min / 5min / 10min / 30min / 1hr / 6hr / 18hr.

• S3, S4 suspend mode
• Ignition On/Off status detectable by SW
• Low battery status detectable by SW
• Ignition enable/disable is jumper selectable
• Shut down system automatically when the system’s internal temperature

is over 80C.

• VTC 2100 will automatically shut down 5 minutes after the duration

of low battery voltage is over 60 sec. User can detect this situation via
software.

• If the ignition is off and the system is still on after 3 minutes, VTC 2100

will shut down automatically.

• If the ignition is off, the user can detect this status via the software.
• If the ignition is turned on again and the power-off delay is in progress,

VTC 2100 will cancel the delay function and will continue to operate
normally.

• If the ignition is turned on again and the power-off delay ended, VTC

2100 will shut down completely will power-on again automatically.

• If the ignition is turned off again and power-on delay is in progress, VTC

2100 will cancel the delay and stay in power-off status.

• If the ignition is turned off again and the power-on delay ended (en-

tered OS already), VTC 2100 will continue to operate normally.

• If the ignition is turned off again and the power-on delay ended (in BIOS

process), VTC 2100 will shut down immediately.

• If VTC 2100 is off, only below 10mA is used.