NEXCOM VTC 1000 User Manual
Page 58
Copyright © 2011 NEXCOM International Co., Ltd. All rights reserved
45
VTC 1000 User Manual
Appendix B: Vehicle Power Management Setup
If the input voltage setting is 12V:
Set the startup voltage to 11.5V and the shutdown voltage to 10.5V.
If the input voltage setting is 12V:
Set the startup voltage to 12V and the shutdown voltage to 11V.
If the input voltage setting is 12V:
Set the startup voltage to 12.5V and the shutdown voltage to 11.5V.
If the input voltage setting is 12V:
Set the startup voltage to 12.5V and the shutdown voltage to 11V.
Startup and Shutdown Voltage Setting (12V)
Startup and Shutdown Voltage Setting (24V)
Advanced
Version 2.14.1219. Copyright (C) 2010 American Megatrends, Inc.
Aptio Setup Utility - Copyright (C) 2010 America Megatrends, Inc.
→←: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit
Startup,Shutdown Setting
Power Management Configuration
** External +5V & +12V Setting **
External Power
** Startup & Shutdown Voltage Setting **
Input Voltage
Startup.Shutdown
**Delay Time Setting**
Power On Delay
Power Off Delay
[Turn Off Both]
12V
[(11.5.10.5)/(23,21)]
Startup,Shutdown
(11.5, 10.5) / (23,21)
(12.0, 11.0) / (24,22)
(12.5, 11.5) / (25,23)
(12.5, 11.0) / (25,22)
Advanced
Version 2.14.1219. Copyright (C) 2010 American Megatrends, Inc.
Aptio Setup Utility - Copyright (C) 2010 America Megatrends, Inc.
→←: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit
Startup,Shutdown Setting
Power Management Configuration
** External +5V & +12V Setting **
External Power
** Startup & Shutdown Voltage Setting **
Input Voltage
Startup.Shutdown
**Delay Time Setting**
Power On Delay
Power Off Delay
[Turn Off Both]
24 V
[(11.5.10.5)/(23,21)]
Startup,Shutdown
(11.5, 10.5) / (23,21)
(12.0, 11.0) / (24,22)
(12.5, 11.5) / (25,23)
(12.5, 11.0) / (25,22)
If the input voltage setting is 24V :
set the startup voltage to 23V and the shutdown voltage to 21V.
If the input voltage setting is 24V :
set the startup voltage to 24V and the shutdown voltage to 22V.
If the input voltage setting is 24V :
set the startup voltage to 25V and the shutdown voltage to 22V.
If the input voltage setting is 24V :
set the startup voltage to 25V and the shutdown voltage to 23V.