NEXCOM VTC 1000 User Manual
Page 17

Copyright © 2011 NEXCOM International Co., Ltd. All rights reserved
4
VTC 1000 User Manual
Chapter 1: Product Introduction
Dimensions
• 180mm (W) x 120mm (D) x 40mm (H) (7.1” x 4.7” x 1.6”)
Construction
• Aluminum top case with metal sheet
Environment
• Operating temperatures:
Ambient with air:
-20°C to 70°C (SSD)
• Storage temperatures: -40°C to 80°C
• Relative humidity: 10% to 90% (Non-condensing)
• Vibration (random): 2g@5~500 Hz with SSD
• Vibration (with SSD)
Operating: MIL-STD-810F, Method 514.5, Category 20, Ground
Vehicle – Highway Truck
Storage: MIL-STD-810F, Method 514.5, Category 24, Integrity Test
• Shock (with SSD)
- Operating: MIL-STD-810F, Method 516.5, Procedure I, Trucks and
semi-trailers=20g
- Crash Hazard: MIL-STD-810F, Method 516.5, Procedure V, Ground
equipment=75g
Certifications
• CE approval
• FCC Class B
• e13 Mark
Power Management
• Power-on delay time is selectable by BIOS to disable and enable in 10sec
/ 30sec / 1min / 5min / 10 min / 15min / 30min / 1hr.
• Power-off delay time is selectable by BIOS to disable and enable in 20sec
/ 1min / 5min / 10min / 30min / 1hr / 6hr / 18hr.
• S4 suspend mode
• Ignition On/Off status detectable by SW
• Low battery status detectable by SW
• Shut down system automatically when the system’s internal temperature
is over 80
°C.
• VTC 1000 will automatically shut down 5 minutes after the duration
of low battery voltage is over 60 sec. User can detect this situation via
software.
• If the ignition is off and the system is still on after 3 minutes, VTC 1000
will shut down automatically.
• If the ignition is off, the user can detect this status via the software.
• If the ignition is turned on again and the power-off delay is in progress,
VTC 1000 will cancel the delay function and will continue to operate
normally.
• If the ignition is turned on again and the power-off delay ended, VTC 1000
will shut down completely and power-on again automatically.
• If the ignition is turned off again and power-on delay is in progress, VTC 1000
will cancel the delay and stay in power-off status.
• If the ignition is turned off again and the power-on delay ended (in BIOS
process), VTC 1000 will shut down immediately.
• If VTC 1000 is off, only below 10mA is used.