beautypg.com

NEXCOM VTC 1000 User Manual

Page 17

background image

Copyright © 2011 NEXCOM International Co., Ltd. All rights reserved

4

VTC 1000 User Manual

Chapter 1: Product Introduction

Dimensions
• 180mm (W) x 120mm (D) x 40mm (H) (7.1” x 4.7” x 1.6”)

Construction
• Aluminum top case with metal sheet

Environment
• Operating temperatures:

Ambient with air:
-20°C to 70°C (SSD)

• Storage temperatures: -40°C to 80°C
• Relative humidity: 10% to 90% (Non-condensing)
• Vibration (random): 2g@5~500 Hz with SSD
• Vibration (with SSD)

Operating: MIL-STD-810F, Method 514.5, Category 20, Ground
Vehicle – Highway Truck
Storage: MIL-STD-810F, Method 514.5, Category 24, Integrity Test

• Shock (with SSD)

- Operating: MIL-STD-810F, Method 516.5, Procedure I, Trucks and

semi-trailers=20g

- Crash Hazard: MIL-STD-810F, Method 516.5, Procedure V, Ground

equipment=75g

Certifications
• CE approval
• FCC Class B
• e13 Mark

Power Management
• Power-on delay time is selectable by BIOS to disable and enable in 10sec

/ 30sec / 1min / 5min / 10 min / 15min / 30min / 1hr.

• Power-off delay time is selectable by BIOS to disable and enable in 20sec

/ 1min / 5min / 10min / 30min / 1hr / 6hr / 18hr.

• S4 suspend mode
• Ignition On/Off status detectable by SW
• Low battery status detectable by SW
• Shut down system automatically when the system’s internal temperature

is over 80

°C.

• VTC 1000 will automatically shut down 5 minutes after the duration

of low battery voltage is over 60 sec. User can detect this situation via
software.

• If the ignition is off and the system is still on after 3 minutes, VTC 1000

will shut down automatically.

• If the ignition is off, the user can detect this status via the software.
• If the ignition is turned on again and the power-off delay is in progress,

VTC 1000 will cancel the delay function and will continue to operate
normally.

• If the ignition is turned on again and the power-off delay ended, VTC 1000

will shut down completely and power-on again automatically.

• If the ignition is turned off again and power-on delay is in progress, VTC 1000

will cancel the delay and stay in power-off status.

• If the ignition is turned off again and the power-on delay ended (in BIOS

process), VTC 1000 will shut down immediately.

• If VTC 1000 is off, only below 10mA is used.