Appendix C: Signal Connection of DI/DO

NViS2310 User Manual

Dry Contact

Each channel can accept 3~24Vdc voltage. And it is able to drive 150mA

current for low level.

The SW2 needs to switch to “OFF” state. The GPO signal will no have a pull

up resistor internally when you switch “SW2” to “OFF” state.

The figure below shows how to connect an external input source to one of

the output channel.

Digital Output

CN14 connector for GPO signal (digital signal output)

The CN14 connector has 4 digital output channels by default. The signal

connection of CN14 support two connected methods for output signal type.

The output signal has two states, one is low level (driven to 0V from GPO

signal) other is open (high voltage is provided from external device).

Wet Contact (default)

The SW2 needs to switch to “ON” state. The GPO signal will have a pull up

resistor to 5V internally when you switch “SW2” to “ON” state. The output

signal has two states, one is low level (driven to 0V from GPO signal ) other

is high level (driven to 5V from GPO signal).

The figure below shows how to connect an external input source to one of

the output channel.

GPO

Register

Port

1

HIGH

0

GND

GPO

Register

Port

1

OPEN

0

GND

External

Internal

GPIO1

GPO5

GPO6

GPIO2

GPIO7

GPO4

GPIO8

GPIO3

GPIO_GND

CN14

9

10

11

12

13

14

15

7

16

VCC5

6

11

5

12

4

13

External

Internal

GPIO1

GPO5

GPO6

GPIO2

GPIO7

GPO4

GPIO8

GPIO3

GPIO_GND

CN14

9

10

11

12

13

14

15

7

16

Resistor

External power