beautypg.com

Digital input, External internal, Dry contact – NEXCOM NViS 2310 User Manual

Page 69

background image

Copyright © 2013 NEXCOM International Co., Ltd. All Rights Reserved.

55

Appendix C: Signal Connection of DI/DO

NViS2310 User Manual

Dry Contact:

Digital Input

CN14 connector for GPI signal (digital signal input)
The CN14 has 4 digital input channels by default.

Wet Contact (default)
The GPI signals have a pull up resistor to 5V internally.

The figure below shows how to connect an external output source to one
of the input channel.

External

Internal

GPIO1

GPI5

GPI6

GPIO2

GPIO7

GPI4

GPIO8

GPIO3

GPIO_GND

CN14

9

10

11

12

13

14

15

7

16

VCC5

6

11

5

12

4

13

1K

1K

External

Internal

GPIO1

GPI5

GPI6

GPIO2

GPIO7

GPI4

GPIO8

GPIO3

GPIO_GND

CN14

9

10

11

12

13

14

15

7

16

Resistor

External power

External

Switch

Port

GPI

Register

ON (Short)

GND

0

OFF (Open)

OPEN

1

External

Switch

Port

GPI

Register

ON (Short)

GND

0

OFF (Open)

HIGH

1

This manual is related to the following products: