Appendix A: Power Consumption

Power Consumption Measurement

Purpose
The purpose of the power consumption test is to verify the power dissipa-
tion of the system and the load of the power supply.

Test Equipment
PROVA CM-07 AC/DC CLAMP METER

Device Under Test
DUT: Sys #1

Test Procedure
1. Power up the DUT and then boot Windows XP.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Run the Intel Kpower program.
5. Run the LAN Packet Counter and Receive program.

Test Data

Sys #1

+12V

Full-Loading Mode

2.18A

Total

26.16W

Standby Mode

0.9A

Total

10.8W