beautypg.com

Programming, Dmx personality, Dmx starting address – ILUMINARC Ilumipod™ Inground Tri-12 IP User Manual

Page 17: Dimmer, Operation

background image

Operation

Ilumipod Inground IP Series User Manual (Rev. 4)

13








Make sure to
press
after selecting an

option. Otherwise, the
product will not save the
new setting. In this case,
the Ilumicode’s display
will show “SEND…























The DMX Starting
Address setting
works with all but
the REMOTE

personality.

Programming

Carry out all the programming procedures indicated below from Ilumicode’s panel. Refer to the
corresponding Menu Map (pages 11 and 12) to learn how the menu options relate to each other
depending on the type of product.

Use and

to change levels in the Menu Map. This is equivalent to moving
right and left respectively. Use and to move forward and backwards
respectively within the Menu Map options.

Press to accept the selected value for an option. This will send that value to the
product(s).

DMX Personality

(All Ilumipod Inground IP products)

1. Go to PERSON and select any DMX personality that matches the product with which

you are working (ignore any other options).

36 IP RGB & Tri-12 IP

36 IP VW

ARC1

ARC+D

ARC FULL

SOLID

SOLID

SPECIAL1

VW

VW+D

2. Make sure to arrange the DMX addresses of all products in the current DMX universe

to avoid address overlapping.

DMX Starting Address

(All Ilumipod Inground IP products)

1. Go to DMX.

2. Select a starting DMX address (001~512).

Dimmer

(All Ilumipod Inground IP products)

1. Go to DIMMER.

2. Select a dimmer curve (OFF or DIM1~4).

DIMMER

Description

OFF

Dimmer curve is linear with fader

DIM1

Non-linear (fastest)

DIM2

Non-linear (fast)

DIM3

Non-linear (slow)

DIM4

Non-linear (slowest)