Signal wiring, External wiring, Power distribution – ILUMINARC Ilumipod™ Inground Tri-12 IP User Manual
Page 12: Signal distribution, Installation
Installation
8
Ilumipod Inground IP Series User Manual (Rev. 4)
The signal cable
must match or
exceed the
electrical
characteristics of the
Belden® 9841 cable for
EIA RS-485 applications.
If you choose to
bury the power or
signal distribution
boxes, make sure that
they are IP67 rated.
Signal Wiring
To provide signal for any of the Ilumipod Inground IP products, you must run a single, IP67
rated DMX signal cable (shielded, 2-conductor, AWG24/2, 6.5 mm external diameter 120
ohm typical impedance) from the signal distribution box into the installation sleeve and the
product’s junction box.
External Wiring
You must run AC power and signal wires from the respective AC and signal distribution
boxes into each of the Ilumipod Inground IP products.
Power Distribution
Connect the bare-ended power cable from the product to a power distribution box as indicated
below.
Signal Distribution
Connect the bare-ended signal cable from the product to a signal distribution box as indicated
below.
(Black)