Signal wiring, External wiring, Power distribution – ILUMINARC Ilumipod™ Inground Tri-12 IP User Manual

Page 12: Signal distribution, Installation

background image

Installation

8

Ilumipod Inground IP Series User Manual (Rev. 4)

The signal cable
must match or
exceed the
electrical

characteristics of the
Belden® 9841 cable for
EIA RS-485 applications.





If you choose to
bury the power or
signal distribution

boxes, make sure that
they are IP67 rated.















Signal Wiring

To provide signal for any of the Ilumipod Inground IP products, you must run a single, IP67
rated DMX signal cable (shielded, 2-conductor, AWG24/2, 6.5 mm external diameter 120
ohm typical impedance) from the signal distribution box into the installation sleeve and the
product’s junction box.

External Wiring

You must run AC power and signal wires from the respective AC and signal distribution
boxes into each of the Ilumipod Inground IP products.

Power Distribution

Connect the bare-ended power cable from the product to a power distribution box as indicated
below.


















Signal Distribution

Connect the bare-ended signal cable from the product to a signal distribution box as indicated
below.






















(Black)