Operation, Ilumicode, Ilumicode panel description – ILUMINARC Ilumipod™ Inground Tri-12 IP User Manual
Page 15: Menu map, White functions menu map
Operation
Ilumipod Inground IP Series User Manual (Rev. 4)
11
4. Operation
When you scroll
through the
menu options,
you will see
many of them that do not
correspond with this menu
map. Skip them, as they
do not work with the
White output products.
If you scroll after
STRB, you will
see the
RED,
GREN, BLUE,
and AMBE
colors. Just
skip them as they do not
work with the VW
products.
Ilumicode
The products in the Ilumipod Inground IP Series lack a control panel. Therefore, they need an
external controller, the Ilumicode device, to change their configuration.
Ilumicode Panel Description
Menu Map
The products in the Ilumipod Inground IP Series have distinct menu maps based on the colors they
produce, whether RGB or White. The Ilumicode controller presents the functions for both types of
products.
White Functions Menu Map
(Ilumipod Inground 36 IP VW)
This menu map shows you which parameters of the Ilumicode controller correspond to the
Ilumipod Inground 36 IP VW product.
Main Level
Programming Levels
Description
DMX
001~512
N/A
Sets the DMX starting address
PERSON
VW
N/A
3-channel: SpectraWhite control
VW+D
4-channel: SpectraWhite control + dimmer
SOLID
1-channel: dimmer
DIMMER
OFF
N/A
Dimmer work in linear mode
DIM 1
Dimmer works in non-linear mode, from fast to
slow.
DIM 2
DIM 3
DIM 4
STATIC
COOL
0~255
Configures the static color and effect
WARM
Button
Function
Exits from the current menu or function
Enables the currently displayed menu or sets the
currently selected value into the selected function
Navigates upwards through the menu list and increases
the numeric value when in a function
Navigates downwards through the menu list and
decreases the numeric value when in a function
Turns the unit on. The unit will turn off automatically
after 30 seconds of inactivity.