Sheet21, Drawing view103, Drawing view104 – Future Automation MLS User Manual
Page 17: Drawing view105, Future automation mls, Rs232, Marine lift swivel mechanism instruction sheet

9
1
2
3
4
5
6
7
8
PIN 1: IN
PIN 6: OUT
PIN 3&4: GROUND
PIN 2: IN
PIN 3: OUT
PIN 5: GROUND
pins
6
1
Sheet 16 of 18
ISSUE: 011
www.futureautomation.co.uk
FUTUREAUTOMATION
MLS
Marine Lift Swivel Mechanism
Instruction Sheet
RS232
Use an RJ11 connector in the
socket marked RS232 on the
control box to operate using RS232.
DETAILS
Baud rate: 9600
Stop bit: 1
Parity: None
Databits: 8
PROTOCOL
ASCI Command
fa_in = Device IN
fa_out = Device UP only
fa_stop = Device STOP
fa_store = STORE MEMORY position
fa_preset = Go to MEMORY position
fa_home = Device UP only
fa_right = Device UP and to RIGHT limit
fa_left = Device UP and to LEFT limit
ALL COMMANDS FOLLOWED BY
CARRIAGE RUTURN