Page 16: Contact closure, Marine lift swivel mechanism instruction sheet

1
8
pins
Once the mechanism is moving, any contact
closure input will cause the lift to stop. There will
then be a short delay before another command
can be issued. This feature should always be
available to the end user for safety reasons.
The emergency stop connector should also be
used to connect other safety devices or switches
Sheet 15 of 18
ISSUE: 011
www.futureautomation.co.uk
FUTUREAUTOMATION
MLS
Marine Lift Swivel Mechanism
Instruction Sheet
Contact Closure
Use an RJ45 connector in the
CC1 socket on the control box
to operate via contact closure.
GROUND
Momentary short to ground to make
lift go UP to HOME position. CC2
Momentary short to ground to make
lift go IN. CC1
Momentary short to ground to make
lift go UP and LEFT. CC3
Momentary short to ground to make
lift go UP and RIGHT. CC4
When 12V is attached, device will go OUT.
When 12V is removed, device will go IN.
DEVICE IN
DEVICE OUT
DEVICE STOP
DEVICE IN LATCHED
N/A
12V LATCH
12V SUPPLY CURRENT LIMITED
BR
W/BR
G
W/BL
W/G
O
W/O
BR
W/BR
O
W/BL
W/O
G
W/G
8
7
6
5
4
3
2
1
ACTION
DESCRIPTION
568
A
568
B
PIN