beautypg.com

4 synchronizing more than 2 nugget units, 5 ltc in latency – Doremi Nugget User Manual

Page 39

background image

5.4 Synchronizing more than 2 Nugget Units

If you have more than 2 Nugget units to synchronize:

Designate one unit as Master and the rest as slaves

Connect the LTC OUT of the Master to an analog video distribution amplifier (an analog
audio DA is more suitable, but a video DA is easier to connect because it has BNC
connectors)

Follow the same synchronization instructions in the previous 2 paragraphs. (change this)

NOTE: We strongly recommend using a DA to distribute the LTC from the Master to multiple
Slave units as opposed to daisy chaining LTC between units, but if a DA is not available, daisy
chaining will be acceptable until a DA is added to the system.

5.5 LTC IN Latency

If you want the Nugget to chase 1 or 2 frames ahead of the incoming LTC, you can set the LTC
IN Latency to 1 or 2. Values up to 5 are allowed, default value is 0.

NUG.OM.000105.DRM

Page 39

Version 3.1

Doremi Labs, Inc.