Dpl barcodes – Datamax S-Class ST-3210 User Manual
Page 66
![background image](/manuals/75149/66/background.png)
56
ST/SV-3210 and ST/SV-3306
DPL Barcodes
Uppercase alpha names will print barcodes with human readable interpretations;
lowercase alpha names will print barcodes only.
Font
Barcode Type
Length
Checksum
Valid Characters
A
3 of 9
Varies
No
0-9, A-Z, -. *$/+% and space
char.
B
UPC-A
11 digits
Yes
0-9
C
UPC-E
6 digits
Yes
0-9
D
Interleaved 2 of 5
Varies
No
0-9
E
Code 128
(A,B, and C)
Varies
M-103
The entire 128 ASCII character
set.
F
EAN-13
12 digits
Yes
0-9
G
EAN-8
7 digits
Yes
0-9
H
Health Industry
Bar Code (HIBC)
Varies
M-43
0-9, A-Z, -$:/. The Host must
supply leading + 's
I
Codabar
Varies:
min 3
No
0-9, -, ., $, :, /, +, and the
start/stop codes: a, b, c, and d.
J
Interleaved 2 of 5
without Bars
Varies
M-10
0-9
K
MSI Plessey
Varies
M-10
0-9. If + is last character,
additional MSI checksum will be
added to the bar code in place of
the + character.
L
Interleaved 2 of 5
(UPC CASE)
13
M-10
0-9
M
UPC 2 digit add.
2 digits
Yes
0-9
N
UPC 5 digit add.
5 digits
Yes
0-9
O
Code 93
Varies
No
All 128 ASCII characters
p
Postnet
Varies
Yes
0-9
Q
UCC/EAN Code
128
19 digits
Yes
0-9
R
UCC/EAN Code
128 K-MART
NON EDI
18 digits
Yes
0-9
S
UCC/EAN Code
128 Random
Weight
Varies:
At least
34 digits
Yes
0-9
T
Telepen
Varies
Yes
All 128 ASCII characters
u
UPS MaxiCode
84
Yes
0-9, A-Z
v
FIM
1 char.
No
A, B, C, or D
z
PDF-417
Varies
Yes
All ASCII characters