Setting up the printer, 0 ac voltage configuration – Datamax S-Class ST-3210 User Manual
Page 17
ST/SV-3210 and ST/SV-3306
7
Setting up the Printer
This section details the connections, loading methods, memory module
installation, and resident ticket formats of the printer.
3.0 AC Voltage Configuration
Depending upon the configuration of the AC Selection Switch and fuse,
the printer is capable of either 115 or 230 VAC single-phase operation.
Before connecting power, check the voltage configuration: (1) locate the
AC Selection Switch and Fuse Holder (containing the fuse) on the Back
Panel, then (2) referencing the table below, ensure that the AC Selection
Switch setting and fuse rating correspond to your AC Source Voltage.
CAUTION
Failure to verify the AC Selection Switch setting and fuse
rating can result in personal injury and/or printer damage.
AC Source Voltage AC Selection Switch
Required Fuse Rating
105 – 125 VAC
115 VAC
1.6 amp / 250V slow-blow
210 – 250 VAC
230 VAC
0.8 amp / 250V slow-blow