Mounting, Shelf placement or stacking, Rack mounting – CUE controlCUE User Manual
Page 6: 6 mounting, Rubber feet, Screws m3 x 6 screw holes cover panels
![background image](https://www.manualsdir.com/files/768541/content/doc006.png)
6
controlCUE Controllers | Mounting
© CUE, a.s. | All Rights Reserved.
Mounting
Shelf Placement or Stacking
Four rubber feet are provided for shelf placement or stacking. Stick the rubber feet near the corner edges on
the bottom side of controlCUE - see picture below.
Rubber feet
Rack Mounting
The Rack Mounting Shelf (CS0449) provides simple solution for installing controllers to the 19” rack. It allows
to install up to two half-rack sized controllers to single 19” unit rack space. All necessary accessories are
supplied with the shelf.
Controller is fixed to the Rack Mounting Shelf by two screws M3 x 6 using female threads on the bottom side
of controller - see picture below. Screws M3 x 6 are bundled with Rack Mounting Shelf. Don’t use longer
screws to avoid damage of PCBs inside the unit.
If you install only one controller use cover panel delivered with the shelf.
12
123
41
2
123
4
SERIAL
IR/SERIAL
GENERAL I/O
RELAY
IR SENSOR
PWR LINK CPU
12
1234
12
123
4
SERIAL
IR/SERIALG
ENERAL I/O
RELAY
IR SENSOR
PW
R
LINK CPU
Screws M3 x 6
Screw holes
Cover panels