beautypg.com

Addressing – CUE irCUE User Manual

Page 9

background image

User Manual irCUE

www.cuesystem.com

Page 9 of 20

6. Addressing

The BUTTON_ID transmitted by the panel is the LINK number used in the programming for button
identification. The value depends on the button position, on Fn button and on a panel ADDRESS too.
Default panel ADDRESS is 0. BUTTON_ID is calculated according a formula.

If Fn is not activated:

BUTTON_ID= (64 * ADDRESS) + Button Code

If Fn is activated:

BUTTON_ID= (64 * ADDRESS) + Button Code + 32

The Fn button changes the first and second function of each button. If Fn is not active, LED above Fn
button is switched off and there is no modification of BUTTON_ID (the button has its first function). If
Fn is active, the LED above Fn button is on and all buttons have their second functions (BUTTON_ID
is shifted by 32).

Every press of the button changes Fn activity. If Fn is active, after 1 minute it is switched off
automatically.

For example, button PLAY has the Button Code 1026. Panel ADDRESS is set to 0. If Fn is not
activated, the pressing of the PLAY button will generate BUTTON_ID: 1026. If Fn is activated, the
pressing of the PLAY button will generate BUTTON_ID: 1058.

For addressing with irCUE Receiver 485 see chapter irCUE Receiver 485 / Addressing.

The button codes are numbers from 1001 to 1032 and they are shown in the following picture.