The address of the receiver can be set up by the Address Switch - see picture above. The
BUTTON_ID sent by irCUE Receiver 485 to the control unit is a BUTTON_ID sent by IR wireless
control panel with an added OFFSET value. Button ID and OFFSET values are calculated according
to the formulas below.
BUTTON_ID (irCUE Receiver 485) = Offset + BUTTON_ID (IR wireless control panel)
Offset = 32 * ADDRESS
ADDRESS is binary coded by DIP switch in the range 0 to 255.
SW1 – ADDRESS bit 0
SW2 – ADDRESS bit 1
SW3 – ADDRESS bit 2
SW 4 – ADDRESS bit 3
SW 5 – ADDRESS bit 4
SW 6 – ADDRESS bit 5
SW 7 – ADDRESS bit 6
SW 8 – ADDRESS bit 7
ADDRESS of irCUE Receiver 485
OFFSET
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
0
0
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
32
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
64
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
3
96
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
...
255
8 160
ON
ON
ON
ON
ON
ON
ON
ON