CIRCUTOR PowerStudio Series User Manual
Page 26

PowerStudio PowerStudio
26 User Manual
• recordGroup: Main field which will identify the XML as a response to the variable
register request.
• period: Register period. Will report on time elapsed between records.
• record: Will Identify each of the records:
dateTime: Date and time of the sample.
field: Standard value register.
fieldComplex: Complex value register
fieldARM: Harmonic value register
fieldFO: Waveform value record
fieldEVQ: EVQ event register
Here are the different types of values that can be returned by this request:
• Standard value registers (voltages, currents, power, energy, etc.).
Field>
id: Variable identifier (device.variable)
value: Value
• Complex value register (PLT, etc.).
fieldComplex>
id: Variable identifier (device.variable)
value: Value
flags: Additional information from the variable formed by the union of one or
more of the following values
♦ 0x0000 The PLT is correct
♦ 0x0001 The PLT calculation has been done with fewer samples
than expected
♦ 0x0002 The PLT calculation has been done with more samples
than expected
♦ 0x0004 The samples used in the PLT calculation do not have an
equidistant separation in the sampling window
♦ 0x0008 Some PST used in the calculation of the PLT contain
events in phase 1
♦ 0x0010 Some PST used in the calculation of the PLT contain
events in phase 2
♦ 0x0020 Some PST used in the calculation of the PLT contain
events in phase 3
♦ 0x0040 Some PST used in the calculation of the PLT are not
complete
• Harmonic value record
element>
…
id: Variable identifier (device.variable)