beautypg.com

3pg-02 terminal descriptions – Delta Electronics Pulse Generator Card PG-02 User Manual

Page 3

background image

3

PG-02 Terminal Descriptions

Terminals

Terminal Symbols

Descriptions

VP

Power source of PG-02 (FSW1 can be switched to 12V or 5V)
Output Voltage: (+12VDC

±5% 200mA) or (+5VDC ±2% 400mA)

DCM

Power source (VP) and input signal (A, B) common

Input signal from Pulse Generator. Input type is selected by FSW2.
Maximum 500KP/Sec

A/O, B/O

PG-02 output signal for use with RPM Meter.
Maximum DC24V 300mA

COM

PG-02 output signal (A/O, B/O) common.


Wiring Notes

The control, power supply and motor leads must be laid separately. They
must not be fed through the same cable conduit / trunking.

1. Please use a shield cable to prevent interference. Do not run control wire parallel to any

high voltage AC power line (220 V and up).

2. Connect shielded wire to

E only.

3. Recommended wire size 0.21 to 0.81mm

2

(AWG24 to AWG18).

4. Wire

length:

Types of Pulse

Generators

Maximum Wire Length

Wire Gauge

Output Voltage

50m

Open Collector

50m

Line Driver

300m

Complementary 70m

1.25mm

2

(AWG16) or above