3.3.5 Programmable Output Y1/Y2/Y3
TSM17C motors feature three optically isolated digital outputs (Y1/Y2/Y3) with common ground.
They can be configured by Step-Servo Quick Tuner software.
• Y1 can be set to signal a fault condition;
• Y2 can be set to indicate whether the motor is in position(dynamic);
• Y3 can be set to control a motor brake.
The output can be used to drive LEDs, relays and the inputs of other electronic devices like PLCs
and counters. Diagrams of various connection types follow.
Do not connect the output to more than 30 volts. The current through the output terminal
must not exceed 100mA.