beautypg.com

5 programmable output y1/y2/y3 – Applied Motion TSM17C-1CG User Manual

Page 19

background image

19

Rev. A

920-0085

TSM17C Hardware Manual

3.3.5 Programmable Output Y1/Y2/Y3

TSM17C motors feature three optically isolated digital outputs (Y1/Y2/Y3) with common ground.

They can be configured by Step-Servo Quick Tuner software.
• Y1 can be set to signal a fault condition;
• Y2 can be set to indicate whether the motor is in position(dynamic);
• Y3 can be set to control a motor brake.
The output can be used to drive LEDs, relays and the inputs of other electronic devices like PLCs

and counters. Diagrams of various connection types follow.

Do not connect the output to more than 30 volts. The current through the output terminal

must not exceed 100mA.

5-24VDC

0VDC

Y1

YCOM

Y2

Y3

User Control

Drives

Y1

YCOM

Y2

Y3

Load

+

-

5-24VDC

Power Supply

This manual is related to the following products: