beautypg.com

2 x1 & x2 digital input – Applied Motion TSM17C-1CG User Manual

Page 16

background image

16

Rev. A

920-0085

TSM17C Hardware Manual

3.3.2 X1 & X2 Digital Input

The TSM17C drives include two inputs: X1 and X2. They accept 5 to 24 volt single-ended or

differential signals. The diagrams below show how to connect them to various commonly used

devices.

+5v to +24v out

X1

X2

X1+

X1-

X2+

X2-

Indexer

with

Sinking

Outputs

Connecting to Indexer with Sinking Outputs

TSM17C

X2

COM

X1

Indexer

with

Sourcing

Outputs

X2+

X2-

X1+

X1-

Connecting to Indexer with Sourcing Outputs

TSM17C

X2+

X2-

X1+

X1-

5 - 24

volt DC

Power

Supply

Using Mechanical Switches

+

TSM17C

This manual is related to the following products: