Str4 maximum motor duty cycle, 34 str4/8 hardware manual – Applied Motion STR4 User Manual
Page 34

34
STR4/8 Hardware Manual
920-0030J
5/12/2015
The actual temperature of the motor depends on how much heat is conducted, convected or
radiated out of it. Our measurements were made in a 40°C (104°F) environment with the motor
mounted to an aluminum plate sized to provide a surface area consistent with the motor power
dissipation. Your results may vary.
STR4 Maximum Motor Duty Cycle
Motor
Connection
Drive Current
Amps, peak of
sine
Max Duty Cycle at 40°C Ambient
24VDC
48VDC
HT17-068
parallel
1.6
100%
see chart
HT17-071
parallel
2
100%
see chart
HT17-075
parallel
2
see chart
see chart
HT17-268
parallel
1.6
100%
see chart
HT17-271
parallel
2
100%
see chart
HT17-275
parallel
2
100%
see chart
HT17-278
parallel
2.4
100%
see chart
HT23-394
parallel
3.4
100%
see chart
HT23-398
parallel
4.5
100%
see chart
HT23-401
parallel
4.5
100%
see chart
HT23-594
parallel
3.4
100%
see chart
HT23-598
parallel
4.5
100%
see chart
HT23-601
parallel
4.5
100%
see chart
HT24-100
4 leads
3.36
100%
100%
HT24-105
4 leads
4.5
100%
see chart
HT24-108
4 leads
4.5
100%
see chart
HT34-485
series
4.5
100%
100%
HT34-486
series
4.5
see chart
see chart
HT34-504
series
3.816
100%
100%
HT34-505
series
3.816
100%
100%