10 str4/8 hardware manual – Applied Motion STR4 User Manual
Page 10

10
STR4/8 Hardware Manual
920-0030J
5/12/2015
power supply.
The tables below and on the next page list the maximum current required for each motor at
several common power supply voltages. Please consider this information when choosing a
power supply.
Table 1: STR4 Power Supply Current
All motors connected as indicated, except HT24 which have four leads.
Switch
Motor
Drive Current
Amps, peak of
sine
Max Power Supply Current (A)
24VDC
48VDC
0
reserved for custom motors
1
2
HT17-278
2.4 parallel
1.6
1.7
3
HT17-068/268
1.6 parallel
1.1
1.1
4
HT17-071/271
2.0 parallel
1.1
1.1
5
HT17-075/275
2.0 parallel
1.1
1.1
6
HT23-394/594
3.4 parallel
1.9
2.0
7
HT23-398/598
4.5 parallel
3.2
3.3
8
HT23-401/601
4.5 parallel
3.2
3.4
9
HT24-100
3.36
2.6
2.3
A
HT24-105
4.5
5.2
3.2
B
HT24-108
4.5
4.3
3.4
C
HT34-485
4.5 series
2.6
2.5
D
HT34-486
4.5 series
2.4
2.7
E
HT34-504
3.816 series
2.1
2.1
F
HT34-505
3.816 series
2.4
2.1