4. USER INTERFACE

4.1 AUTOMATIC OPERATION MODE

• Selecting Automatic Mode:
Press the AUTO button so that the indicator is lit.

The START indicator will also illuminate. (See Figure
4.1 & Figure 4.2)

• Operation Status:
During Automatic Mode, the Operation Status

Indicators will light to show the current phase of
Automatic Mode operation. Refer to Section 8 for
details on the phases of Automatic Operation Mode.
(See Figure 4.2)

• Set Automatic Tension Set Point:
Set the Tension Set Point by adjusting the AUTO

knob. The Tension Set Point will be displayed on the
front panel display. (See Figure 4.3 & Figure 4.4)

• Front Panel Display
The front panel display shows information on the

current tension set point and control output level by
default. Press the r & s buttons on the front panel
to change the display information. Refer to Section
4.3 for details. (See Figure 4.4)

• Tension Display
The measured tension is displayed on the front

panel. (See Figure 4.5)

• Output Bar Graph
Eleven LEDs indicate 0 to 100% output. The LEDs

indicate increments of 10%. The value is rounded to
the nearest 10% increment. (See Figure 4.6)

• Output ON/OFF Toggle
The

Output ON button toggles the control output

ON and OFF. When the indicator is lit, the output is
enabled and controlled by the TC920V. The output
level is controlled by the state of the Automatic Mode
operation. When pressed, the indicator lamp will
turn off, the Operation Status indicators will clear,
the output displayed on the bar graph and display
will both read “0%”, and the external control output
will shut off. (See Figure 4.7)

FIGURE 4.1

Selecting Automatic Mode

FIGURE 4.2

Operation Status Indicators

FIGURE 4.4

Front Panel Display

FIGURE 4.6

Output Bar Graph

FIGURE 4.7

Output ON/OFF Toggle

FIGURE 4.5

Tension Display

FIGURE 4.3

Automatic Tension Setpoint

AUTO

MAN

START

AUTO

STOP

AUTO

MAN

TEN. SET

OUTPUT

60lbF

45%

TENSION

OUTPUT

0

50

100%

OUTPUT

ON