beautypg.com

Service instructions parts list specifications – Nexen TCD600E 912145 User Manual

Page 23

background image

FORM NO. L-20348-F-0705

23

AC Power ..................................................................................... 115VAC/230VAC, 0.3A/0.6A, 50/60Hz, 1 Phase
Torque Control Output ............................................................................ 0-10VDC@10mA, 4 - 20mA@600 max.
Diameter Output ...................................................................................................................................... 0-5VDC@10mA
Alarm Outputs ...................................................................................................... 30Volts@100mA (optically isolated)
Switch Inputs (Start, Stop, Hold) ..........................................................................................................15VDC@1.5mA
Ambient Temperature ............................................................................................................ 32ºF - 120ºF (0ºC - 50ºC)
Weight .........................................................................................................................................................1 pound [1.6kg]
Proximity Switch ...............................+15 VDC, NPN, Normally Closed, Open Collector 40 mA Sink, minimum

Logic Level: V

LOW

<1 VDC, V

HIGH

> 2.25 VDC

Minimum Pulse Width: 100 Microseconds

Encoder ...........................................................................+15 VDC, Open Collector Output, 12 mA Sink, minimum

Logic Level: V

LOW

<1 VDC, V

HIGH

> 2.25 VDC

Minimum Pulse Width: 600 Nanoseconds

Ultrasonic Sensor ............................................................................................................. +24 VDC, 0-10 VDC Output

TCD 600 Controller - English/Spanish ........................................................................................912123
TCD 600 Controller - English/French ..........................................................................................912145
Ultrasonic Sensor .............................................................................................................................912127
Optional - Mounting Bracket for TCD 600 .................................................................................912129
Optical Encoder ................................................................................................................................912140
Optional Encoder Mounting Bracket ............................................................................................912141
Proximity Switch ................................................................................................................................912068

The TCD 600 has no field serviceable parts and must be returned to Nexen for repair.

SERVICE INSTRUCTIONS

PARTS LIST

SPECIFICATIONS

This manual is related to the following products: