beautypg.com

Caution – Nexen TL60-A 951243 User Manual

Page 8

background image

8

FORM NO. L-20138-U-0912

PROXIMITY SENSOR

NOTE: A ground wire is not required.

1. Install the Dowel Pin (Item 4) into the Torque Limiter

(See Figure 7).

2. Using Cap Screws (Item 54), secure the Limit

Switch (Item 55) to the Mounting Bracket (Item 3)
(See Figure 7) using Mounting Plate (Item 57).

3. Using Cap Screws (Item 2), mount the Mounting

Bracket (Item 3) onto the Torque Limiter (See Figure
7).

4

54

55

3

2

57

FIGURE 7

AIR CONNECTIONS

All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8373.1: 2001
Class 4.4.3 quality.

Figure 8

CAUTION

Do not use rigid pipe and tubing when making

air line connections. Torque on the air line

caused by bearing drag may be relieved by

resting the air line on a support parallel to the

torque limiter center-line. Align the air inlet

port to the six o'clock down position to allow

condensation in the air chamber to drain out

of the exhaust port.

This manual is related to the following products: