beautypg.com

Troubleshooting – Nexen TL60-A 951243 User Manual

Page 12

background image

12

FORM NO. L-20138-U-0912

TROUBLESHOOTING

SYMPTOM

PROBABLE CAUSE

SOLUTION

Failure to engage.

Insufficient air pressure to the Torque

Limiter.

Check the air lines for leaks and replace damaged

air lines.

Damaged or leaking O-ring Seals.

Replace the O-ring Seals.

Failure to

disengage.

Broken Compression Springs.

Replace the Compression Springs.

Air not exhausting from the Quick Exhaust

Shuttle Valve.

Replace the Quick Exhaust Shuttle Valve.

Ratcheting.

Insufficient air pressure to the Torque

Limiter.

Check the air lines for leaks and replace damaged

air lines.

Damaged or leaking O-ring Seals.

Replace the O-ring Seals.

Nuisance tripping.

Proximity Sensor not properly adjusted.

Adjust the Proximity Sensor(See ADJUSTMENTS).

FIGURE 12

Dowel

Pin

Ball Seat

(Included in

Drive Flange

Assembly)

Ball

(Included in

Drive Flange

Assembly)

Drive

Flange

Assembly

Backing

Plate

Hub

Ball

Bearings

Drive

Ring

Rotary

Seal

Ball

Bearing

Compression

Spring

O-ring

Seal

Piston

Back-Up

Ring Seal

Proximity

Sensor

Ball

Bearing

O-ring

Seal

Back-Up

Ring Seal

Mounting

Bracket

This manual is related to the following products: