FORM NO. L-20138-U-0912

INTRODUCTION

HUB PREPARATION

NOTE: This section pertains only to units with a customer machined bore. If your Torque Limiter has been

bored by Nexen, proceed with INSTALLATION.

TL-A

After the Hub has been finished bored, drill and tap the
Hub for Set Screws. Set Screw locations are over the
keyway, and at 90

o

of the keyway. Models TL10-A and

TL15-A require two Set Screws located on the Drive
Flange end of the Hub. Models TL20-A and higher
require two Set Screws located on both ends of the
Hub (Refer to Table 1 for Set Screw sizes).

TL-AC

After the Hub has been finished bored, make four saw
cuts in the Drive Flange end of the Hub. Locate the first
saw cut 45

o

from the keyway and the other three saw

cuts at 90

o

increments from the first saw cut (Refer to

Table 2 for saw cut dimensions).

TABLE 1

TABLE 2

Nexen's air-engaged, single-position Torque Limiters provide overload protection for power transmission equipment,
thus protecting machinery and product from jam-ups and resultant down time expense.

The totally enclosed construction of Nexen's Enclosed Torque Limiter allows for usage in wet or humid conditions and
is acceptable for use in federally inspected meat and poultry plants.

A Proximity Sensor (located on the Torque Limiter) senses the onset of an overload condition and releases air pressure
at the 3-way valve to provide split second disengagement of the Torque Limiter.

The single position feature resets in the same position when the unit is engaged, providing exact timing of two
components.

SET SCREW SIZES

MODEL

US

METRIC

QTY

TL10-A10

10-24

M5-0.8

2

TL15-A

10-24

M5-0.8

2

TL20-A

1/4-20

M6-1.0

4

TL30-A

5/16-24

M6-1.0

4

TL40-A

3/8-24

M10-1.5

4

TL50-A

3/8-24

M10-1.5

4

TL60-A

1/2-13

M12-1.75

4

TL70-A

1/2-13

M12-1.75

4

TL80-A

1/2-13

M12-1.75

4

SAW CUT DIMENSIONS

MODEL

CUT WIDTH

CUT DEPTH

TL20-AC

0.06" [1.52 mm]

0.96" [25.4 mm]

TL30-AC

0.06" [1.52 mm]

0.96" [25.4 mm]

TL40-AC

0.06" [1.52 mm]

0.96" [25.4 mm]

TL50-AC

0.06" [1.52 mm]

0.96" [25.4 mm]

TL60-AC

0.06" [1.52 mm]

0.96" [25.4 mm]

TL70-AC

0.06" [1.52 mm]

0.96" [25.4 mm]

TL80-AC

0.06" [1.52 mm]

0.96" [25.4 mm]