StorCase Technology 9-Bay 4U SCSI Ultra320 User Manual
Page 24
InfoStation User Interface
15
InfoStation 9-Bay User's Guide - Rev. C02
StorCase Technology, Inc.
The following steps show how to set-up the drive bay SCSI ID via the Display and Control Panel.
NOTE:
Press CANCEL at anytime to exit the menu system and return to the Default
Display. The menu system will automatically cancel after 15 seconds of
User inactivity.
NOTE:
The drive bay SCSI ID can only be set when the drive bay is inactive (e.g.
when Drive Ready LED is OFF).
1.
Press ENTER at the Default Display so that
display = Status.
2.
Press DOWN until display = Bay Cfg.
3.
Press ENTER so that display = SCSI ID.
4.
Press ENTER again until display = BAY1:0.
The drive bay can be configured only when the
SCSI ID number is blinking. If the drive bay
contains a drive or is online, SCSI ID will not blink.
5.
Press ENTER to change the SCSI ID.
The * next to the ID number indicates current
SCSI ID.
6.
Press UP or DOWN to change the SCSI ID value.
7.
Press ENTER to accept the change.
The ? indicates possible SCSI ID conflict with the
other drive bays in the same enclosure.
8.
Press UP or DOWN to scroll through each bay
and repeat steps 5-7 to change bay configura-
tion.