SCSI Channel Configurations

StorCase Technology, Inc.

InfoStation User's Guide - Rev. B01

SCSI CHANNEL CONFIGURATIONS

Termination of the SCSI Bus at the VHDCI Connectors

CAUTION:

When using the double-stacked VHDCI connectors (Port A-1 & A-2)

simultaneously, offset VHDCI cable connectors must be used for proper

fit. Failure to use proper cables may result in damage to the I/O repeater

module VHDCI connectors!

NOTES:

Port-A1 and Port-A2 are connected internally.

Port-A requires an external terminator if:

1. It is connected to the end of an external SCSI cable.

2. It is "open" and not in use. In this case, only Port B is used.

Port-B does not require a terminator (it is terminated internally).

Figure 8: InfoStation VHDCI Connectors

(I/O Repeater Module)

IFS_8a

PORT A-1

PORT A-2

PORT B

(TERMINATED)

ERR

ACT

SCSI

LVD/SE

ULTRA160