Receiving frame front panel – StorCase Technology S20A120 User Manual

Page 11

background image

4

Introduction

StorCase Technology, Inc.

S20A120 User's Guide - Rev. A01

Figure 3: Receiving Frame Front Panel

Receiving Frame Front Panel

(Figure 3)

•

Key Lock/Drive Power Switch- This key switch assures proper seating of the

drive carrier within the receiving frame, turns power to the drive carrier on and off,

and prevents unauthorized removal or installation of the carrier. For the computer

to access data on the DE300 drive, the key must be turned counterclockwise to the

locked position. The key can be configured as either fixed or removable as shown

in Appendix C.

•

Unit ID Number Indicator- This LED displays the physical address of the DE300

device carrier if the carrier is installed and locked in the receiving frame or if the

carrier is removed from the receiving frame. If the carrier is installed but not locked

in the receiving frame, a "u" will be displayed to indicate an unlocked condition. The

unit ID number is selected by means of the unit ID select switch inside the receiving

frame using a special alignment tool supplied with the DE300 (see Figure 9).

•

Activity Indicator- A small dot next to the unit ID number illuminates to indicate when

the host computer is accessing the data on the DE300 carrier. This dot will flash

during communication with the host computer.

•

Device Spin Down/Up Timer- This timer controls the length of time that the activity

indicator flashes during device spin down/up, providing a visual indication of drive

activity. Refer to Figure 10 for timer settings.