StorCase Technology DE100i-SWU2 User Manual

Page 19

background image

Kingston Technology Company

DE100i-SWU2 User's Guide - Rev. A00

12

Installation

Mounting
Holes (Right)

Mounting
Holes (Bottom)

Front of Unit

Mounting
Holes (Left)

0086

IMPORTANT NOTE: In order to use remote ID selection from a computer or

expansion chassis, the Unit ID number on the Data Express

receiving frame must be set to '0' with the provided alignment

tool. Refer to the section "Selecting the Unit Number" later in

this manual for the Unit ID selection procedure.

4.

With the drive carrier locked in place inside the receiving frame, install the

Data Express into the 5.25” drive opening in the computer or expansion

chassis. Use the appropriate guides to position the Data Express, and fasten

it into place with the four (4) #6-32 x 1/4” screws provided. Figure 9

illustrates the location of the mounting holes. Mounting holes are provided on

each side and the bottom of the receiving frame to accommodate a variety of

mounting configurations. Use the mounting holes which best suit the

computer or expansion chassis configuration.

Figure 9: Receiving Frame Mounting Holes

5.

Adjust the front of the receiving frame so the carrier slides freely in and out

on the receiving frame guides. The position of adjoining peripheral units may

require adjustment.

6.

To connect the drive to a Remote Activity LED in the computer system or

expansion chassis, connect the appropriate cable(s) to the receiving frame

motherboard as shown in Figure 5. Connect W1 Pins 9 and 10 to a remote

activity LED.

7.

Connect the I/O interface cable from the host adapter to the receiving frame.

The Pin 1 indicator on the cable must be properly aligned. Refer to Figure 5

for the correct Pin 1 location.

NOTE:

No onboard termination is provided on the DE100i-SWU2.

External termination must be provided.