Introduction
3
DE100i-SWU2 User's Guide - Rev. A00
Kingston Technology Company
General Description
The Kingston Technology Data Express
®
DE100i-SWU2 is composed of a receiving frame
which supports Ultra2 (LVD) Wide Single-Ended/Differential SCSI interfaces and fits within
a 5.25" half-height peripheral slot (Figure 2). The receiving frame contains one removable
drive carrier designed to provide durable and reliable mounting for one 3.5" form factor
SCSI drive.
The Data Express allows a drive to be removed and transported to another Data Express-
equipped computer or expansion chassis, and also provides the ability to secure sensitive
data by removing and storing the drive safely for future use. Up to fifteen (15) DE100i-
SWU2 Data Express units can be attached to one host adapter, with the addition of the
DX1/200-U2/RH Hot Swap/Repeater Isolator Board.
NOTES: DE100i-SWU2 requires LVD chassis and cabling.
DE100i-SWU2 supports implementations with a maximum of 2 drives
(without the DX1/200-U2/RH Hot Swap/Repeater Isolator Board).
This User's Guide describes the steps required to install the Kingston Data Express
DE100i-SWU2 removable enclosure inside a computer peripheral bay or external
expansion chassis. This guide supplements documentation provided with the host
computer system, operating system, and the drive to be installed within the Data Express
carrier.
Figure 2: DE100i-SWU2 Receiving Frame and Carrier