BATTERY MEMORY SET AND CALL OUT
[ B A T T M E M O R Y 1 ]
E N T E R S E T - >
B A T T T Y P E
L i P o
B A T T V O L T S
7 . 4 V ( 2 S )
The charger can store up to 10 different charge/discharge profiles for your convenience, and the
stored profiles can be recalled quickly without having to go through the setup process.
When you are willing to alter the parameter value in the program, press START/ENTER to make it
blink then change the value with INC or DEC. The value will be stored by pressing START/ENTER
once.
Note: All following screen are taking 2S(7.4V) LiPo battery for example.
Enter the battery memory program.
(10 different charge/discharge profiles can be stored).
Set the battery type(LiPo/LiFe/LiIon/LiHV/NiMH/NiCd/Pb).
Set the voltage and number of cells(1S-8S).
1. Battery Memory Set
START/ENTER
DEC
INC
DEC
INC
Regenerative Discharge transforms most of the energy from the discharging battery pack to the Lead
Acid battery powering the charger. The regenerative discharge current can reach to 40A Max. It works
only when the power source is 6P or 12P Lead Acid battery.
For factory default setting, the Regenerative Discharge function is disabled. Please follow below steps
to active it,
When the power source is 6P or 12P Lead Acid battery and the Regenerative Discharge function is
active, all discharge modes will switch to generative discharge modes automatically.
For example,
Note1: Please make sure to set the right current and cut voltage of the Lead Acid battery and change
the setting when you change the power source every time.
If the power source is DC power supply, the Regenerative Discharge will be off automatically.
BATTERY MEMORY SET AND CALL OUT
REGENERATIVE DISCHARGE
P R O G R A M S E L E C T
S Y S T E M S E T - >
U S E R e g e n e r a t i v e
D i s c h a r g e r ? > Y
L i P o D I S C H A R G E
2 . 0 A 7 . 4 V ( 2 S )
L i P o R E G E N D S C
2 . 0 A 7 . 4 V ( 2 S )
Note2:
If the power source is 8P, 9P or 10P Lead Acid battery, but not 6P or 12P, even you active
regenerative discharge function, it will be off automatically.
Note3:
If the Lead Acid battery is full charged in regenerative discharge mode, the charger will alarm 5
times(Like bi-bi-bi-bi-bi), then switch to internal discharge automatically until it finishes
discharge progress.