beautypg.com

页 18, Various information during the process, Warning and error message – SkyRC 6x80+ Blue Version Charger User Manual

Page 18

background image

VARIOUS INFORMATION DURING THE PROCESS

VERSION
1.00

LOAD FACTORY SET
ENTER

Press and hold the Start/Enter dial for 3 seconds
to load the factory set.

This screen shows the version.

SELECT

You can inquire various information on LCD screen during charging or
discharging process. When you rotate the dial counterclockwise, the
screen will display the user’s settings.
And also you can monitor the voltage of individual cell by rotating the
dial clockwise when the individual connection cable is linked to the
Lithium battery being processed.

Ext. Temp 0C
Int. Temp 26C

It comes to the final voltage when the program
ended.

Present input voltage.

This screen shows the internal temperature.

Displayed safety timer is turn on and duration of
time in minutes.

Displayed capacity cut-off function is turn on and
the setting value of capacity.

The battery is connected with balance lead, you
can check voltage of each cell in the battery pack.

VARIOUS INFORMATION DURING THE PROCESS

4.19 4.15 4.18V
0.00 0.00 0.00V

32

33

6X80 Plus

6X80 Plus

It incorporates a variety of functions for the systems to verify processes
and the state of the electronics. In case of an error the screen will
display the cause of error and emit an audible sound.

Incorrect polarity connected.

The battery is interrupted.

CONNECT ERROR
CHECK MAIN PORT

The Battery connection is wrong.

The cell number is wrong.

CELL NUMBER
INCORRECT

Voltage of one cell in the battery pack is too high.

CELL ERROR
HIGH VOLTAGE

Voltage of one cell in the battery pack is too low.

CELL ERROR
LOW VOLTAGE

The internal temperature of the unit goes too high.

INT.TEMP.TOO HI

DC IN TOO LOW

Input voltage less than 11V.

Input voltage higher than 18V.

DC IN TOO HIGH

BATTERY WAS FULL

The battery voltage is higher than the maximum
voltage which the user sets when charging in
balance mode.

WARNING AND ERROR MESSAGE

CELL ERROR
VOLTAGE-INVALID

Voltage of one cell in the battery pack is invalid.

The external temperature of the unit goes too high.

EXT.TEMP.TOO HI

OVER CHARGE
CAPACITY LIMIT

The battery capacity is more than the maximum
capacity which the user sets.

OVER TIME LIMIT

The charging time is longer than the maximum
charging time which the user sets.

BALANCE CONNECT
ERROR

The balance connect is wrong.