VARIOUS INFORMATION DURING THE PROCESS
VERSION
1.00
LOAD FACTORY SET
ENTER
Press and hold the Start/Enter dial for 3 seconds
to load the factory set.
This screen shows the version.
SELECT
You can inquire various information on LCD screen during charging or
discharging process. When you rotate the dial counterclockwise, the
screen will display the user’s settings.
And also you can monitor the voltage of individual cell by rotating the
dial clockwise when the individual connection cable is linked to the
Lithium battery being processed.
Ext. Temp 0C
Int. Temp 26C
It comes to the final voltage when the program
ended.
Present input voltage.
This screen shows the internal temperature.
Displayed safety timer is turn on and duration of
time in minutes.
Displayed capacity cut-off function is turn on and
the setting value of capacity.
The battery is connected with balance lead, you
can check voltage of each cell in the battery pack.
VARIOUS INFORMATION DURING THE PROCESS
4.19 4.15 4.18V
0.00 0.00 0.00V
32
33
6X80 Plus
6X80 Plus
It incorporates a variety of functions for the systems to verify processes
and the state of the electronics. In case of an error the screen will
display the cause of error and emit an audible sound.
Incorrect polarity connected.
The battery is interrupted.
CONNECT ERROR
CHECK MAIN PORT
The Battery connection is wrong.
The cell number is wrong.
CELL NUMBER
INCORRECT
Voltage of one cell in the battery pack is too high.
CELL ERROR
HIGH VOLTAGE
Voltage of one cell in the battery pack is too low.
CELL ERROR
LOW VOLTAGE
The internal temperature of the unit goes too high.
INT.TEMP.TOO HI
DC IN TOO LOW
Input voltage less than 11V.
Input voltage higher than 18V.
DC IN TOO HIGH
BATTERY WAS FULL
The battery voltage is higher than the maximum
voltage which the user sets when charging in
balance mode.
WARNING AND ERROR MESSAGE
CELL ERROR
VOLTAGE-INVALID
Voltage of one cell in the battery pack is invalid.
The external temperature of the unit goes too high.
EXT.TEMP.TOO HI
OVER CHARGE
CAPACITY LIMIT
The battery capacity is more than the maximum
capacity which the user sets.
OVER TIME LIMIT
The charging time is longer than the maximum
charging time which the user sets.
BALANCE CONNECT
ERROR
The balance connect is wrong.