beautypg.com

页 13, Nimh/nicd battery program, Pb( lead-sulphuric acid) battery program – SkyRC 6x80+ Blue Version Charger User Manual

Page 13: Charging of pb battery, Discharging of pb battery

background image

22

23

6X80 Plus

6X80 Plus

CHARGE/DISCHARGE & DISCHARGE/CHARGE CYCLE
OF NIMH/NICD BATTERY

- +

- +

Battery
type

Elapsed
time

Battery
voltage

Discharged
or charged
capacity

Discharge
or charge
current

> 3 seconds

NiMH CYCLE
CHG

>DCHG 1

NiMH 1.0A 7.42V
C>D 022:45 00890

You can set up sequence on the left and the
number of cycles on the right. Range of the
cycle number is 1-5.

Press Mode/Stop key to stop program, you
can rotate the Start/Enter dial to alter the
current.

Mode
Stop

SELECT

SELECT

NIMH/NICD BATTERY PROGRAM

Discharge
current

Battery
type

Battery
voltage

Elapsed
time

Discharged
capacity

NiMH 0.1A 7.42V
DSC 022:45 00890

The screen indicates the discharging state.
You can rotate the Start/Enter dial to alter
discharge current and repress the dial to
store the value. Press Mode/Stop button to
stop discharging.
The audible sound indicates the end of
process.

Press
Dial

PB( LEAD-SULPHURIC ACID) BATTERY PROGRAM

This is programmed for charging Pb (lead-sulphuric acid) battery with
nominal voltage from 2 to 20V. Pb batteries are totally different from
NiMH or NiCd batteries. They can only deliver relatively lower current
comparing to their capacity, and similar restrictions definitely apply to
charge. So the optimal charge current will be 1/10 of the capacity. Pb
batteries must not be charged rapidly. Always follow the instruction
supplied by the battery manufacturer.

CHARGING OF PB BATTERY

Battery
type

-

Elapsed
time

+

Charge
current

Battery
voltage

- +

Charged
capacity

> 3 seconds

Set up the charge current on the left and the
nominal voltage of the battery on the right.
The charge current ranges from 0.1 to 10.0A
and the voltage should be matched with the
battery being charged. Start the charge
process by pressing and holding the dial for
3 seconds.

The screen displays the state of charging
process. To stop charging forcibly, press
Mode/Stop button once.
The audible sound indicates end of process.

DISCHARGING OF PB BATTERY

- +

- +

Set discharge current on the left and final
voltage on the right. The discharge current
ranges from 0.1 to 5.0A.
To start the process, press and hold the
Start/Enter dial for 3 seconds.

SELECT

SELECT

Mode
Stop

SELECT

SELECT

> 3 seconds

Mode
Stop

Press
Dial

Press
Dial