Red LED:

Comes on solid on start-up (power on) in standard mode

Comes on blinking on start-up (power on) in Programming mode

When active RPM is reached, LED will blink (even if activation
wire is not triggered)

Green LED:

Comes on solid when activation wire is triggered (on whenever
powered up in RPM limiter mode)

Blinks retard count on start-up (power up) when Retard Mode
enabled.

Settings:

Controlled by two (2) ten position switches

o

Two (2) switches for selecting 1000 rpm and 100 rpm scale

o

View module with wires exiting top, and 0 at 12 o’clock on RPM selector switches

Notes:

The LNC-001 will not trigger at RPM levels below 1500 rpm

Changes to the rpm switch point settings must be done with the ignition off

o

The switch positions are only read on start up

Example settings:

2500 rpm activation point for launch control

o

Left (X000) rpm switch on position 2

o

Right (0X00) rpm switch on position 5

0

5

6

78

9

1

2 34

0

5

6

78

9

1

2 34

100's Switch

1000's Switch

RPM Programming

Switches

7200 rpm activation point for RPM limiter

o

Left (X000) rpm switch on position 7

o

Right (0X00) rpm switch on position 2

0

5

6

78

9

1

2 34

0

5

6

78

9

1

2 34

100's Switch

1000's Switch

RPM Programming

Switches