Window / Door Sensor is used to monitor doors or windows that
open and close. When these doors / windows are open or
closed, the sensors will transmit a signal to the control panel to
notify the user. These sensors consist of 2 parts, one is the
transmitter, the other is the magnet.
Before installing the sensor, remove the battery isolator by pulling out the yellow
tab. Once the isolator is removed, the corresponding zone LED on the control
panel will flash and buzzer will beep. If the magnetic contact is closed, the
beeping will stop.
Note:
- Both Window/Door Sensors have been programmed at the factory. They are
Zone 1 Sensor 1 and Zone 2 Sensor 1. Trigger the sensor and listen to the
beeping and zone LED to determine which one is zone 1 and which is zone 2.
Testing:
After mounting the sensor, test the sensor by opening and closing the door or
window. Open the door or window will result in the followng:
1. Beeping - The number of beep represents the zone number.
2. Zone LED flashing - Number of flash represents the sensor number.
Mounting the Sensor
The transmitters should be mounted on the door frame or window frame by
double sided tape. The magnet should be mounted on the door or window by
either double sided tape or screws. Make sure the magnet is aligned with the
red marking on the transmitter. If the surface of the frame is flat enough, double-
sided foam tape is sufficient, otherwise, it is recommended to screw the
mounting plate to the frame, then apply double sided tape. After mounting the
sensor, if the AAA+ logo is inverted, remove the front cover and rotate it so the
AAA+ logo is in the upright position.