ADVANCED PROGRAMMING
Auto Mute
When a sensor is triggered in alert mode, audio warning will be emitted, either
beep or alarm. For example, if a door is opened, the beep will not stop until the
door is closed. If the door is open for 2 hours, the beep will go on for 2 hours.
There are times that this is not desired. With the auto mute feature enabled, the
beep will go on for only 20 seconds. After that, even if the sensor remains open,
the beep will stop only the zone LED will flash to indicate the sensor is triggered.
Beep will go on again if the sensor is closed and opened again.
Note: Auto Mute only functions when the control panel is in alert mode (disarmed).
If the control panel is in alarm mode (armed), a triggered sensor will result in
entry delay or instant alarm.
Factory Default: This feature was disabled for all zones at the factory.
To enable auto mute feature, follow the instructions below.
1
2
3
4
[PROG]
[MPIN]
Enter Program-
ming mode
Enter master
password to
programming mode
3 beeps for valid
password. 1 long beep
for invalid password.
[6]
Select Auto Mute
Enable / Disable
After [6] is entered, some
zone LEDs will flash or
stay on. This indicates
whether Auto Mute is
enabled or disabled.
Disable
Auto Mute:
[1] to [5]
Enable
Auto Mute:
[6] to [0].
Select which
zone you would
like to enable /
disable auto mute.
Refer to the diagram
below to select the
appropriate setting.
If auto mute is enabled,
that zone LED will be on.
If it is disabled, the LED
will flash. You are allow
to make multiple changes
before terminating
programming mode.
[PROG]
when
finished.
Terminate
programming
mode.
PROG LED will be off, and
you will hear 3 beeps.
Step
Keys
Function
Description