beautypg.com

Cleaning and maintenance, Caution: do not vacuum if pieces are hot – Desa CGCDV36PR User Manual

Page 32

background image

www.desatech.com

116200-01L

32

CAUTION: Wear gloves and

safety glasses while handling

or removing broken glass. Do

not remove if glass is hot. Keep

children and pets away from

glass.

If glass has been broken, carefully remove
glass door (see Removing/Replacing Glass
Door
, page 25). Vacuum all glass pieces with
a shop vac.

CAUTION: Do not vacuum if

pieces are hot.

Use only the tempered glass door replace-
ment intended for this fireplace (see Replace-
ment Parts
, page 37 for detail on ordering).
No substitutions may be made. See Remov-
ing/Replacing Glass Door
, page 25 for instruc-
tions for replacing glass door.

WARNING: Do not operate

fireplace with the glass door

unlatched, removed, cracked

or broken.

PILOT AND BURNERS

• Remove ember material before cleaning

burners and replace when cleaning is
complete.

• Burner and controls should be cleaned

with compressed air to remove dust, dirt
or lint.

• Use a vacuum cleaner or small, soft bristled

brush to remove excess dust, dirt or lint.

LOGS

• If you remove logs for cleaning, refer to

Installing Lava Rock and Glowing Embers,
page 26, to properly replace logs.

• Use a vacuum cleaner to remove any

carbon buildup on logs.

• Replace log(s) if broken. See Replacement

Parts on page 37.

• Replace ember material periodically

as needed. See Replacement Parts on
page 37.

VENTING SYSTEM

Conduct annual inspection of venting system
following these guidelines:
1. Check areas of venting system that are

exposed to the weather for corrosion (rust
spots or streaks and, in extreme cases,
holes). Have these items replaced im-
mediately by a qualified service person.

2. Remove vent cap and shine a flashlight

into vent. Remove any foreign material.

3. Check for evidence of excessive con-

densation. Continuous condensation can
cause corrosion of caps, pipes and fittings
and can be caused by having excessive
lateral runs, too many elbows or exterior
portions of the system being exposed to
cold weather.

4. Inspect joints to verify that no pipe section

or fitting has been disturbed and loos-
ened. Check mechanical supports such
as wall straps for rigidity.

CLEANING AND MAINTENANCE