Hall Research HR-4P User Manual
Page 11
Programmable Serial Controller
11
Any I/O configured as inputs may have the current status read by clicking the I/O Status button.
Any I/O configured as outputs may have the output state set by selecting the appropriate control button.
RTS is an OUTPUT, CTS is an INPUT. Action based configuration strings can be created for the CTS Input only.
The HR-4P unit is assigned a common address value of 01 by factory default, and it is just part of the unit‟s info for
your convenience and serves no other purpose (you can tag your units with a number between 1 and 255 for future
reference).
After using the Connect button and establishing communication with a HR-4P unit, this tab will show the units
Firmware Version Number as well as its programmed Address.
Figure 11
– I/O Control
IR
The IR tab is used to configure the IR capabilities of the HR-4P unit. A compatible IR Detector and Emitter are
required to fully utilize the IR features.
When the IR is configured as an Input, the HR-4P unit can learn any supported IR codes from the user‟s remote
control. These IR codes can be stored into 1 of 32 IR Memory locations in the unit.
IR codes stored in memory can have an 8 character name associated with it, making it easier to be identified later.
o
Check the IR Enabled box
o
To LEARN IR Codes
Select the Input radio button and click Upload
Install IR Detector on HR-4P Unit
Click the LEARN button
Press IR Remote Control button while pointing at IR Detector
Store code learned into IR Memory Location with name if desired
o
To SEND IR Codes