Go Power! GP-SW1000 User Manual
Page 7

GPSW-1000/2000/3000
___________________________________________________________
7
f.
Frequency:
Typical North American setting is 60 Hz. Set dip switch S4 to “0” for 50
Hz and “1” for 60 Hz.
g.
Power Save:
Puts inverter to sleep until a load is present.
h.
Strain Relief Clamp:
Provides strain relief for Hard Wire AC Output option.
i.
AC Outlet:
Ground Fault Protected (GFCI) Outlet sockets available: North America.
3.1.2 Rearview (GPSW3000 and GPSW2000)
Operation of the inverter without a proper ground connection
may result in an electrical safety hazard.
a.
Ventilation port:
Do not obstruct, allow at least one inch for airflow.
b.
Remote Port:
Allows the customer to use any 2 wire switch to turn the inverter ON
and OFF. Ex. Toggle switch or light switch.
c.
Chassis Ground: