beautypg.com

Go Power! GP-SW1000 User Manual

Page 14

background image

GPSW-1000/2000/3000

___________________________________________________________ 

14 

 

approximately 3.0 W from the battery.

5.2 Input Level (battery voltage) indicator

The GPSW600, GPSW1000, GPSW2000 and GPSW3000 Input Level LED
changes colour from green to yellow to red as battery voltage decreases from a
resting voltage of 12.7 V - 10.5 V (12 V) or 25.4 V – 21V (24 V). The Input Level
LED changes colour from green to yellow to red as battery voltage increases
from a resting voltage of 12.7V – 15.0 V (12 V) or 25.4 V – 30.0 V (24 V).

5.3 Load Level Indicator

The Load Level LED Indicator changes color from green to yellow to red as the
load is increased. The Load Level LED Indicator will be red at peak wattage or
peak load.

The Load Level LED Indicator should be green or yellow for long-term operation.

Short-term operation is possible with the load indicator in the red area. If the load
rises to dangerous levels, the inverter will protect itself and shut down.

5.5 Status Indicator (GPSW1000, GPSW2000 and GPSW3000)

The status LED indicator will display the operating condition of the inverter. A
solid green LED is normal. A flashing green LED indicates the inverter is in
power save mode (see Power Saving). A red LED, flashing or otherwise,
indicates a fault; see



Table 1: Inverter power states

State

LED

Description

Over voltage
protection

Red LED blinking
fast

Over voltage protection indicates
that the inverter has shut itself down
because its input voltage is over:

12 V: 15.0 ~ 16.0 V DC
24 V: 30.0 ~ 32.0 V DC

Under voltage
protection

Red LED blinking
slowly

Under voltage protection indicates
that the inverter has shut itself down
because its input voltage is lower
than:

12 V: 10.0 ~ 10.5 V DC
24 V: 20.0 ~ 21.0 V DC