beautypg.com

Go Power! GP-SW1000 User Manual

Page 19

background image

GPSW-1000/2000/3000

___________________________________________________________ 

19 

 

indicator on, load
in excess of:
3000 W : 250 A
(12V) or 125 A (24
V); 2000 W: 170A
(12V) or 85A
(24V);
1000 W: 90 A
(12V) or 45 A (24
V);

shutdown

continuous operation required.

No output voltage,
Over Temp
indicator on, load
less than:
3000 W : 250 A
(12V) or 125 A (24
V); 2000 W: 170 A
(12V) or 85 A
(24V);
1000 W: 90 A (12
V) or 45 A (24 V);

Thermal
shutdown

Improve ventilation, make sure ventilation
openings in inverter are not obstructed,
reduce ambient temperature.

No output voltage,
Over Load
indicator on.

Short circuit
or wiring
error.

Check AC wiring for short circuit or improper
polarity (hot and neutral reversed).

Very high
power load

Remove or reduce load

8.0 Maintenance

Very little maintenance is required to keep your inverter operating properly. You
should clean the exterior of the unit periodically with a damp cloth to prevent
accumulation of dust and dirt. At the same time, tighten the screws on the DC
input terminals.


9.0 Disclaimer of Liability & Warranty

Go Power!

TM

provides the following limited 2 year warranty (“Warranty”) coverage

as applicable to the purchaser (“Purchaser”) of the Go Power!

TM

branded product

(“Product”) directly from Go Power!

TM

The following constitutes the terms and

conditions of that limited warranty.

9.1.1 What the Go Power! Warranty Covers and for How Long

Subject to the exclusions and claim procedure set out below, Go Power!

TM

warrants for a period of 2 years from the date of purchase at the point-of-sale to
the original end-user customer (“Sale Date”), that the Go Power!

TM

Product

This manual is related to the following products: