Maintenance – Glow-worm Ultracom2 sxi User Manual
Page 49
![background image](/manuals/736835/49/background.png)
0020092785_02 - 05/10 - Glow-worm
- 47 -
19.4.1
Pump (head only)
• Drain the boiler heating circuit as described in the
appropriate chapter "Draining".
• Disconnect the electrical plug (26) from the main board.
• Disconnect the electrical plug (25) from the pump head.
• Remove the four cap head screws (27).
• Carefully remove the pump head (28) together with cable.
Do not strain cable.
• Reconnect wiring to new pump head and fit cover.
• Fit the new pump head by repeating the operations in
reverse.
19.4.2
Safety discharge valve
• Drain the boiler heating circuit as described in the
appropriate chapter "Draining".
• Undo the safety discharge valve union and remove from the
pipework (7).
• Remove the securing clip (6) and withdraw the safety
discharge valve (8).
• Fit new ‘O’ ring. Refill, vent and pressurise the boiler.
19.4.3
Automatic air vent
• Drain the boiler heating circuit as described in the
appropriate chapter "Draining".
• Remove the retaining clip (29).
• Remove the automatic air vent (20).
• Fit the new automatic air vent and ‘O’ ring ensuring the vent
cap is left loose.
• Refill, vent and pressurise the boiler.
19.4.4
Low water pressure sensor
• Drain the boiler heating circuit as described in the
appropriate chapter "Draining".
• Disconnect the electrical lead (15).
• Remove the retaining clip (17), remove the low water
pressure sensor (16).
• Fit the new low water pressure sensor.
• Refill vent and pressurise the boiler.
19.4.5
bypass
• Drain the boiler heating circuit as described in the
appropriate chapter "Draining".
• Remove the retaining clip (23) to remove the bypass screw (24).
• After replacing the bypass, refill, vent and pressurise the
boiler.