Code Parameter
Unit Description
factory
setting
Modifiable
parameter
d.71 Maximum temperature setting for
heating outlet
°C
Select a value between 50°C and 80°C.
75
yes
d.90 Detection of eBUS controller
-
0 = Not detected
1 = Detected
-
no
• Press on button or under the symbol to access the
parameter to modify.
• Press on button or under the symbol to modify the
value of the parameter.
• Repeat the process for each parameter modified.
• Press for more than 3 seconds on the button
to exit
the configuration menu.
Code Parameter
Unit Description
factory
setting
Modifiable
parameter
d.08 Current state of the 230V room thermostat
-
230V room thermostat :
0 = open (no heating),
1 = closed (heating mode).
-
no
d.09 Flow temperature set point from external eBus control
°C
External eBus set value.
-
no
d.10 Pump status
-
0 = off
1 = on
-
no
d.16 Current state of the 24V room thermostat
°C
0 = open (no heating),
1 = closed (heating mode)
-
no
d.17 Flow or Return temperature monitoring
°C
Temperature regulation on flow (radiator) or return
(under-floor heating) temperature sensor.
0
yes
d.21 DHW status
-
0 = DHW function disabled
1 = DHW activated
-
no
d.22 DHW mode (eBus and direct connection to board)
-
0 = off
1 = on
-
no
d.23 Central heating mode
-
0 = CH not available (summer mode)
1 = CH available (winter mode)
-
no
d.25 DHW mode
-
DHW loading enabled or disabled by Appliance
Interface or Ebus or external controls.
-
no
d.33 Speed setpoint of fan
rpm
Fan speed is displayed between 0 and 99.
Multiply the displayed value by 100.
-
no
d.44 Digitalized ionisation voltage
V
Display the digitalized ionisation voltage
-
no
d.68 Unsuccessfull ignitions at first attempt
-
Display the number of unsuccessfull ignitions at first
attempt.
-
no
d.69 Unsuccessfull ignitions at second attempt
-
Display the number of unsuccessfull ignitions at
second attempt.
-
no
d.80 Operating hours in heating mode
h
Display the number of operating hours in heating
mode. Multiply the displayed value by 100.
-
no
d.81
Operating hours in domestic hot water mode (ebus
control only and direct thermostat connection to board
only)
h
Display the number of operating hours in domestic
hot water mode. Multiply the displayed value by 100.
-
no
d.82 Number of burner starts in heating mode
-
Display the number of burner starts in heating
mode. Multiply the displayed value by 100.
-
no
d.83 Number of burner starts in DHW mode (ebus control
only)
-
Display the number of burner starts in DHW mode.
Multiply the displayed value by 100.
-
no
d.93 Device Specific Number
-
Select the product code of the appliance:
12sxi = 18
18sxi = 19
30sxi = 20
18
19
20
yes
d.96 Factory reset
-
All parameters stored in EEPROM (main board +
appliance interface) are reset to factory settings if
this function is activated.
0 = deactivated
1 = activated
0
yes
13.2.2
After Sales Service settings
• Press for more than 7 seconds on the button
to
access the configuration menu. The screen displays "0".
• Press on button or under the symbol and enter the
After Sales Service password.
• Press on
to validate. The screen displays the
parameter "00" and its value "XX”.