Code Parameter

Unit Description

factory

setting

Modifiable

parameter

d.71 Maximum temperature setting for

heating outlet

°C

Select a value between 50°C and 80°C.

75

yes

d.90 Detection of eBUS controller

-

0 = Not detected

1 = Detected

-

no

• Press on button or under the symbol to access the

parameter to modify.

• Press on button or under the symbol to modify the

value of the parameter.

• Repeat the process for each parameter modified.

• Press for more than 3 seconds on the button

to exit

the configuration menu.

Code Parameter

Unit Description

factory

setting

Modifiable

parameter

d.08 Current state of the 230V room thermostat

-

230V room thermostat :

0 = open (no heating),

1 = closed (heating mode).

-

no

d.09 Flow temperature set point from external eBus control

°C

External eBus set value.

-

no

d.10 Pump status

-

0 = off

1 = on

-

no

d.16 Current state of the 24V room thermostat

°C

0 = open (no heating),

1 = closed (heating mode)

-

no

d.17 Flow or Return temperature monitoring

°C

Temperature regulation on flow (radiator) or return

(under-floor heating) temperature sensor.

0

yes

d.21 DHW status

-

0 = DHW function disabled

1 = DHW activated

-

no

d.22 DHW mode (eBus and direct connection to board)

-

0 = off

1 = on

-

no

d.23 Central heating mode

-

0 = CH not available (summer mode)

1 = CH available (winter mode)

-

no

d.25 DHW mode

-

DHW loading enabled or disabled by Appliance

Interface or Ebus or external controls.

-

no

d.33 Speed setpoint of fan

rpm

Fan speed is displayed between 0 and 99.

Multiply the displayed value by 100.

-

no

d.44 Digitalized ionisation voltage

V

Display the digitalized ionisation voltage

-

no

d.68 Unsuccessfull ignitions at first attempt

-

Display the number of unsuccessfull ignitions at first

attempt.

-

no

d.69 Unsuccessfull ignitions at second attempt

-

Display the number of unsuccessfull ignitions at

second attempt.

-

no

d.80 Operating hours in heating mode

h

Display the number of operating hours in heating

mode. Multiply the displayed value by 100.

-

no

d.81

Operating hours in domestic hot water mode (ebus

control only and direct thermostat connection to board

only)

h

Display the number of operating hours in domestic

hot water mode. Multiply the displayed value by 100.

-

no

d.82 Number of burner starts in heating mode

-

Display the number of burner starts in heating

mode. Multiply the displayed value by 100.

-

no

d.83 Number of burner starts in DHW mode (ebus control

only)

-

Display the number of burner starts in DHW mode.

Multiply the displayed value by 100.

-

no

d.93 Device Specific Number

-

Select the product code of the appliance:

12sxi = 18

18sxi = 19

30sxi = 20

18

19

20

yes

d.96 Factory reset

-

All parameters stored in EEPROM (main board +

appliance interface) are reset to factory settings if

this function is activated.

0 = deactivated

1 = activated

0

yes

13.2.2

After Sales Service settings

• Press for more than 7 seconds on the button

to

access the configuration menu. The screen displays "0".

• Press on button or under the symbol and enter the

After Sales Service password.

• Press on

to validate. The screen displays the

parameter "00" and its value "XX”.

INSTALLATION